46 Troubleshooting
To correct the problem, perform the following steps:
1.
Issue the following command from the vxWorks shell:
nvramTLanSpeedSet 10100
nvramELanSpeedSet 10
nvramELanDuplexSet 1
2. Reboot the card.
Several methods are available to check the connections speed and duplex:
•
faceplate LEDs
• itgCardShow
•
from vxWorks, linkGetOperation 1 or 0
> linkGetOperation 0
value = 100 = 0x64 = ‘d‘
NOV 26 08:42:17 tShell: Info T-LAN in Autonegotiation
Mode.
NOV 26 08:42:17 tShell: Info T-LAN Operating in 100Mbps,
Full-Duplex mode.
-> linkGetOperation 1
value = 10 = 0xa
->
NOV 26 08:42:40 tShell: Info E-LAN Operating in 10Mbps,
Half-Duplex mode.
New VGMC software or IP Phone firmware testing
To try a new VGMC version or a new IP Phone firmware version on just a
few telephones, or to perform testing at the customer site without affecting
all users, you can create a new node. You must add another card (or
reconfigure an existing card) to the system but assign a new node number
that is different from the existing node number. Configure the card as a
Leader because each node must have a leader. You can then reconfigure
selected IP Phones to register with the new card (that is, change the
S1/S2 address and node number on the IP Phones). When the IP Phone
reboots, it registers with the new node. All the unmodified IP Phones
continue to use the existing node.
When you complete the testing, remove (or reconfigure) the card, and
reconfigure the IP Phones to the original settings.
Nortel Communication Server 1000
Troubleshooting Guide for Distributors
NN43001-730 02.02 31 December 2009
Copyright © 2008-2009 Nortel Networks. All Rights Reserved.
.