MGC four-character LED faceplate display 397
Use of the four-character LED display during MGC boot
When the system boots, the diagnostic information from the hardware and
firmware sanity tests appears on the faceplate. The messages that appear
on the four-character LED display during MGC bootup are shown in the
following table. Further design investigation is required to confirm that all
suggested messages during bootup are possible.
Table 115
Messages displayed on the four-character LED display during MGC bootup
Message Description
BOOT
This is the first message when display becomes
active.
POST
Power on self test message appears while the
MGC performs hardware system tests during
system power up.
PASS
Power on self test pass.
EXXX
Error code where XXX is a numeric value. An
error code appears if a serious system error is
detected.
LOAD
Application software is loading.
In normal operation the messages appear in the following order: BOOT,
POST, PASS, LOAD. If a fatal self-test error occurs, then PASS and LOAD
do not appear. Instead an error code appears.
Use of the four character LED during MGC normal operation
After the boot loader loads the CSP and starts to run, you can use the
faceplate display for diagnostic information.
During normal operation, the four-character LED displays the superloop
and shelf number of the Media Gateway 1000E (MG 1000E) with MGC.
If an error occurs that requires a diagnostic message to appear, then
the display cycles between displaying the cabinet number and the error
code. Each item appears for 20 seconds. The following table shows the
messages that appear.
Table 116
Messages displayed on the four character LED during MGC normal operation
Message Description
EXXX
Error code where XXX is a numeric value. An
error code appears if a serious system error is
detected.
Nortel Communication Server 1000
Troubleshooting Guide for Distributors
NN43001-730 02.02 31 December 2009