VoIP command reference 173
Where:
•
the query string is a sequence of expressions, linked together by
&&, each expression consists of three parts: opcode1, operator and
opcode2. The query string is the same as defined in the isetSecGet
command
• ServerID can be either 1 or 2 to indicate whether S1 or S2 settings
have to be updated
•
Action is the action byte that can be 1, 6 or 7. Port is the port number
to be set
• default port value is 4100 if Action is 1 or 6, and 4101 if Action is 7
[nortel@bvw0 ~]$ isetSecUpdate "Encryption == INSEC" 1 7
4101
=== TPS ===
Updating sets...
----------------
IP Address Type Set-TN Encryption Action DTLS Cap.
------------------ ---------- ------------- ------------
-------- ----------
192.168.25.117 1140 096-00-00-27 INSEC 1 -> 7 YES
192.168.25.118 1140 096-00-00-28 INSEC 1 -> 7 YES
192.168.25.
168.25.120 1120 096-00-00-30 INSEC 1 -> 7 YES
192.168.25.121 1210 096-00-00-31 INSEC 1 -> 7 YES
192.168.25.122 1220 096-00-00-32 INSEC 1 -> 7 YES
Total sets updated = 6
isetShow, isetShowByTN, isetShowByIP
Syntax:
isetShow
isetShowByTN
isetShowByIP
These commands list every IP Phone registered with the TPS. For each
telephone, the IP Phone status, type of registration, time up (registered to
TPS), virtual TN, MAC address, type of IP Phone, firmware and UNIStim
signaling versions, and the RUDP ports for the IP Phone and TPS are
shown. The isetShowByTN and isetShowByIP commands display the
output list in order by TN and IP address, respectively, while the isetShow
command lists the IP Phones in order of registration.
Enter the isetShow command at the CLI of any card in a VGMC node
along with the TN or IP address of a particular IP Phone to print this IP
Phone information, along with the identification of the card with which the
Nortel Communication Server 1000
Troubleshooting Guide for Distributors
NN43001-730 02.02 31 December 2009
Copyright © 2008-2009 Nortel Networks. All Rights Reserved.
.