Appendix B
To understand the timing report, first right-click on your mouse button when you are on
the schematic window. Select “worst path” to highlight the most timing critical path as
shown in Figure 3 and compare this with your timing report.
Figure 3
Now it is time to open the timing.rpt file under “synthesis/report” directory and examine
its contents.
a
module_clock
ff3
fa
mx1
ff8
sel
b
d
q
cout
sumcin
b
a
d
q
out
a
0104
module_clock
time
arrive = 0
arrive = 8.05
arrive = 28.17
arrive = 35.46
arrive = 43.50
T = 10
delay = 8.05
delay = 20.12 delay = 7.29 delay = 8.04
SET UP VIOLATION = 10 - 43.50 = -33.50
SET UP VIOLATION = 10 - 43.50 = -33.50SET UP VIOLATION = 10 - 43.50 = -33.50
SET UP VIOLATION = 10 - 43.50 = -33.50